Lesson 7 – L: Launch Your Learning: How Do We Match Solar Supply to Energy Demand in a Mini-Grid?

L: Launch Your Learning

Comparing a Load Profile (Demand) to Daily Solar Production (Supply)

Illustration of a solar-powered healthcare clinic showing how available electricity is prioritized during normal operation and power outages. Rooftop solar panels capture sunlight and generate electricity, labeled "Solar Supply." Inside the clinic, electrical demand is divided into two categories. Priority loads, highlighted in yellow, include a vaccine refrigerator and emergency lighting that remain powered because they are essential for health and safety. Non-critical loads, highlighted in blue, include extra ceiling fans and a laptop charging area that operate only when sufficient power is available. A callout labeled "Energy Demand" explains that electricity powers essential devices and systems inside the building. A flow diagram at the bottom summarizes the process: Sunlight → Electricity Generated → Power to the Clinic → Priority Loads Keep Running → Non-Critical Loads Use Available Power, concluding with the message: "Better Health. Stronger Futures. Sustainable Energy."

Load Profiles and Supply Tables

When engineers design a solar mini‑grid for a real school, clinic, or neighborhood, they start by building a load profile. This is a detailed list of every device that will use electricity (lights, fans, computers, chargers), how much power each one needs (in watts), how many of them there are, and how many hours they run in a typical day. From that table, they calculate daily energy demand for each device and then add them up to find the total daily energy the community needs. 

Next, they create a daily supply table for the solar panels. They list the panel power rating, how many panels are installed, and how many sun‑hours the site gets. Using those values, they estimate daily solar energy supply for the whole system. By comparing the total demand (from the load profile) with the total supply (from the daily supply table), engineers can see if the design is likely to work or if it will fall short. If demand is greater than supply, they have to make trade‑offs: add more panels, reduce run‑time on some devices, remove non‑critical loads, or protect priority loads like clinic refrigerators and emergency lighting first. 

In other words, load profiles and daily supply tables are planning tools. They turn a vague idea like “power a school with solar” into specific numbers so engineers can answer questions such as: 

  • Will this system meet the school’s needs on a typical day? 
  • Which devices use the most energy over time? 
  • What changes are needed to keep critical loads running when energy is limited? 

To Create a Load Profile:

  1. List each load in the mini-grid scenario. 
  2. Calculate daily energy for each load using power × hours. 
  3. Add the loads to find total daily demand. 
  4. Estimate daily solar supply using: panel power × number of panels × sun-hours.
  5. Compare demand and supply. 
  6. Decide whether the system is likely to meet the need. 

Mini-Grid Data Demand Table (Load Profile)

  

 

 

  

 

 

  

 

 

  

 

 

  

 

 

  

 

 

  

 

 

  

 

 

Total daily demand

To Create a Supply Table:

  1. Write the panel power rating in watts for each panel type. 
  2. Write how many panels of that type are in the system. 
  3. Write the number of sun-hours per day for the site. 
  4. Multiply panel power × number of panels × sun-hours to find daily solar energy in watt-hours. 
  5. Repeat for each panel group if there is more than one. 
  6. Add all of the daily solar energy values to find the total daily supply. 

Mini-Grid Daily Supply Table (Solar Production)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total Daily Supply 

Example: Small Clinic

A small clinic wants solar power for: 

  • 4 LED lights in exam rooms 
  • 2 ceiling fans in the waiting area 
  • 1 vaccine refrigerator 
  • 1 phone‑charging station (multi‑port) 

Mini-Grid Data Demand Table (Load Profile)

An infographic outlining the various devices in a small clinic that require power, calculating their total daily energy use.
An infographic showing the solar supply at a small clinic, using four solar cells and calculating the total daily supply.

In this example, daily supply (5000 Wh) is greater than daily demand (2700 Wh), so the system is likely to meet the clinic’s needs under typical conditions.

A bar graph comparing the solar energy supply versus demand at a small clinic. Total daily demand is 2700 Wh and total daily supply is 5000 Wh.

An engineer still needs to consider reliability, weather, battery storage, and constraints like budget or roof area, but the tables show that the basic energy balance works. 

Pause and Think

  • Are you comparing watts or watt-hours?  
  • Which load in your list uses the most total energy in a day?  
  • If demand is greater than supply, what problem does that create?

Key Idea

A solar system must be sized around daily energy use, not just around whether a panel produces power at one moment.